How Do I Clear a Clogged 3D Printer Nozzle, and Why Does It Keep Clogging?
A clicking extruder and thin or missing extrusion usually mean a clog. Here's how Prusa and Bambu Lab say to clear one, starting with a cold pull, and what they say causes clogs to keep coming back.
Disclosure: Some links in this post are affiliate links. The Tinkerverse may earn a commission if you buy through them, at no extra cost to you.
Start with a cold pull if filament still loads, or heat the nozzle higher and push the clog out if it won’t load at all. If clogs keep coming back, the usual causes are wet or poor-quality filament, printing too cold or too fast, or too much heat around the extruder.
How to tell it’s a clog
Prusa lists the signs: filament doesn’t come out of the nozzle at all, or comes out unevenly, prints much thinner lines, or curls up and sticks to the nozzle when purged. Partial clogs often show up mid-print, even after filament loaded fine. Another common sign is a clicking or ticking sound from the extruder. Prusa explains that the click is the extruder motor skipping steps because it needs more force than it’s allowed to push.
Prusa also points out that a clogged hotend isn’t the same as a clogged nozzle. Material can jam higher up, such as in the PTFE tube, so swapping the nozzle doesn’t always fix it. Bambu Lab makes a similar split between clogs in the extruder and clogs in the nozzle.
Clearing it
Prusa’s order is:
- Cold pull. If filament loads and unloads but still causes trouble during the print, Prusa says a cold pull is the place to start. You soften filament inside the nozzle, let it cool until it’s partly solid, then pull it out along with the debris stuck to it. Bambu Lab describes the same process.
- Force it out. If filament won’t load at all, Prusa says to soften the clog by raising the nozzle temperature and pushing it through. On its MK3-family printers, Prusa uses 260 °C after PLA or 280 °C after PETG or ABS, waits about two minutes, then pushes a thin cleaning needle 1-2 cm into the nozzle from below. Prusa warns never to feed the needle in from the top, and never to load filament while it’s inserted.
- Take the hotend apart. If that fails, the clog may be above the nozzle, and Prusa’s guide covers checking the PTFE tube and hotend parts.
Temperatures and steps differ between printers. Both Prusa and Bambu Lab publish model-specific guides, so follow the one for your machine. Bambu Lab says that if a nozzle can’t be cleared, you should replace it.
Why it keeps happening
Bambu Lab’s guides list the most common causes of repeat clogs:
- Printing too cold or too fast. If the filament doesn’t have time to melt fully, it can block the nozzle. Bambu Lab says to check the temperature for your filament, and at very high speeds to slow down or raise the temperature slightly.
- Wet or poor-quality filament. Bambu Lab recommends measuring filament diameter with calipers (1.75 ± 0.03 mm), storing filament sealed or in a dry box, and drying moisture-sensitive materials before printing.
- Heat around the extruder. In a hot enclosure, soft filaments such as PLA and PETG can soften and get flattened by the drive gear. Bambu Lab suggests lowering the bed temperature where possible and opening the door or top cover.
- Switching materials. After a high-temperature filament, Bambu Lab says to purge it out at a higher temperature with the new filament before printing something like PLA.
- Fiber-filled filaments. Bambu Lab recommends a 0.6 or 0.8 mm nozzle for these and says not to use a 0.2 mm nozzle with them.
Bambu Lab also recommends a cold pull at least once a month as routine maintenance, especially when you switch between filament types.